Home
 Jets
Introduction
Jet Pump General Info
Introduction to
Jet Versatility

Principle of
Operation

Model Selection
Guide

Pumping Liquids
with Liquid

Pumping Liquids
with Steam

Pumping Gases
with Steam/Gas

Pumping Gases
with Liquid

Heating Liquids
In-Tank

Heating Liquids
In-Line

Mixing Liquids
Transporting Solids
Additional Jet
Products

Problems/Solutions
Using Jets

Eductor Application
Form

OnLine Jet
Sizing Application

 Gages & Gagecocks
 Introduction
 Armored Flat Glass
 Gages

 Glass Information
 Low/Medium/High
 Pressure Flat Glass
 Gages

 Large Chamber,
 Weld Pad & Ultra
 High Flat Glass
 Gages

 Steam/Water Flat
 Glass Gages

 Offshore Gage
 Glasses

 Valves (Gagecocks)
 Series 100, 200, 300
 & 400

 Series 500, 700,
 550, 750 & 600

 Tubular Glass Gages
 Series N2, K2, K3 &
 N6 & N7

 Magnetic Liquid
 Level Gages

Introduction
Magnetic Gage General Info
Follower/Flag Style Indicators
Point Level Control Measurement
Continuous Level Measurement
Top Mount & Mini
Options & Accessories
Magnetic Gage Application Form
 Sight Flow
 Indicators &
 Sight Windows

Introduction
ANSI
Dual-Window
Lined
Full-View
Threaded Window Indicators
Angled
Threaded Sight Windows
Indicator and Window Accessories
Sanitary
Sanitary Sight Windows
 Electronic Level
 Instrumentation

Introduction
New Wave Capacitance
Explosion-Proof & Non-Leak Probes
Point Level Switches
Continuous Level Transmitters
Ultrasonic Gap Switches
Ultrasonic Continuous Level Transmitters
Electronic Liquid Level Measurement Application Form
 Boiler Trim
 Products

Introduction
Series 1A
Series 2A
Series 4A
Series 12A
Series 12B
Water Columns
Steam/Water Flat Glass Gages
 Literature
 Contact Us/
 Locate Distributor

 News
 FAQ
 Distributor Login
 Tyco Flow Control


 Search

320 Locust Street
Prophetstown, IL 61277
(815) 537-2311 Phone
(815) 537-5764 Fax
eMail: Click Here

 
 

Straight Pattern/OS&Y Flat Glass Gagecocks

Series 500

 

 

 

1500lb. ANSI rating -- Pressures to
4000 psi @ +100°F[27600 kPa
@ +38°C]
Temperature Range from
-20°F to +750°F [-29°C to +399°C]
Design Features
The 500 series includes models 520R and 530R with these standard features:
  • Straight pattern
  • Outside screw and yoke
  • Solid shank vessel connection
  • Gage connection: Model 520R ­ Union / Model 530R ­ Rigid
  • Ball check shutoff
  • Threaded renewable seat
  • Backseating stem
A variety of optional features are available when specified.

Optional materials can be specified for the Gagecock body and trim. (Trim consists of the stem,stem packing retainer, ball check and seat.) Standard and optional materials conform to AISI or ASTM Specifications.

ASME Boiler Code
Series 500 Gagecocks that are acceptable for ASME Boiler Code are available as an option. Gagecocks with this option are supplied with ball check shut-offs omitted.

Series 700

  1500lb. ANSI rating -- Pressures to
4000 psi @ +100°F[27600 kPa
@ +38°C]
Temperature Range from
-20°F to +750°F [-29°C to +399°C]

Design Features
The 700 series includes models 720R, 730R and 780R with these standard features:

  • Offset pattern
  • Outside screw and yoke
  • Solid shank vessel connection
  • Gage connection: Model 720R-Union / Model 730R-Rigid / Model 780R-Stuffing Box
  • Ball check shutoff
  • Threaded renewable seat
A variety of optional features are available when specified.

Optional materials can be specified for the Gagecock body and trim. (Trim consists of the stem, stem packing retainer, ball check, and seat.) Standard and optional materials conform to AISI or ASTM Specifications.

ASME Boiler Code
Series 700 Gagecocks that are acceptable for ASME Boiler Code are available as an option. Ball check shut-off can be omitted; or the Model 720R and 780R can have a vertical rising lower ball check and horizontal, leaky upper ball check.

Series 550/750

  1500lb. ANSI rating -- Pressures to
4000 psi @ +100°F[27600 kPa
@ +38°C]
Temperature Range from
-20°F to +400°F [-29°C to +204°C]

The"Arrester" Fugitive Emission Valve
Environmental pollution is a global issue. Environmental regulations impacting plant operations include Gagecocks. The "ARRESTER" OS&Y Gagecocks are utilized with gage glass, mag gage or other apparatus when process fluid vapors or gases are considered to be environmentally harmful.

Penberthy's "ARRESTER" Gagecocks are individually serialized and tested to meet EPA emission test requirements. Each set of Gagecocks (550R/750R Gagecock) is shipped with its individual test report that certifies less than 5 ppm methane equivalent leak rates using Kalrez® packing. Kalrez®/ Zymaxx™, API 607 III Edition Fire Test qualified, is a packing material option.

Models 551R/751R are available with type-accepted packing, rated to leak rates of 500 ppm methane equivalent.

Optional materials of construction can be specified for the Gagecock body and trim. (Trim consists of the stem, stem packing retainer, ball and seat.) Reference Penberthy Material Specification sheets for optional materials.

Model 530R and 730R center-to-center dimensional information corresponds to the fugitive emission 550R/551R and 750R/751R Gagecocks, respectively.

Series 600

  Pressures to 6000 psi @ +250°F
[41400 kPa @+121°C]
Temperature Range from
-50°F to +250°F [-46°C to +121°C]

Design Features
The 600 series includes model 630J with these standard features:

  • Offset pattern
  • Union bonnet
  • Union vessel connection
  • Rigid gage connection
  • Ball check shutoff
  • Threaded renewable seat
A variety of optional features are available when specified.

Optional materials can be specified for the Gagecock body and trim. (Trim consists of the stem, stem packing retainer, ball check, and seat.) Standard and optional materials conform to AISI or ASTM Specifications.

Pressure/Temperature Range
Model 630J Gagecocks are rated for pressures up to 6000 psi [41400 kPa] over a temperature range of -50°F to +250°F [-46°C to +121°C]. Optional O-ring materials and vessel tail pipe can be used to increase temperature capability.


 Copyright © 2008 Tyco Flow Control. All rights reserved.